Have a question?
Message sent Close

UET60312 – Advanced Diploma of ESI – Power Systems Operations

Electricians Fixing the Electric Lines

This sector covers the delivery of electricity to customers, including homes and businesses.

UET60312 Advanced Diploma of ESI – Power Systems Operations

Release 2

UET60312 Advanced Diploma of ESI – Power Systems Operations

Modification History

Release

Action

Core/Elective

Details

Points

2

Add

Group A

TLIF2010A Apply fatigue management strategies

30

2

Add

Group A

TLIF3063A Administer the implementation of fatigue management strategies

50

Description

Scope:

Those gaining this qualification will be able to acquire additional skills and knowledge needed for a career in system operation.

Pathways Information

Not applicable.

Licensing/Regulatory Information

Not applicable.

Entry Requirements

Not applicable.

Employability Skills Summary

Not applicable.

Packaging Rules

Completion requirements

The requirements for granting this qualification will be met when competency is demonstrated and achieved for:

  • All the Core competency standard units, defined in the Core Competency Standard Units table below and
  • A combination of Elective competency standard units to achieve a total weighting of 1090 points in accordance with the Elective Competency Standard Units table below.
  • All the required prerequisite competency standard units have been met.

Core Competency Standard Units

All Core competency standard units to be achieved

Weighting Points

UEENEED104A

Use software for engineering applications

40

UEENEEE124A

Compile and produce an energy sector detailed report

60

UEENEEE083A

Establish and follow a competency development plan in an electrotechnology engineering discipline

120

UEENEEE101A

Apply Occupational Health Safety regulations, codes and practices in the workplace

20

UETTDREL15A

Respond to power systems technical enquiries and requests

40

UEENEEE104A

Solve problems in d.c. circuits

80

UEENEEE107A

Use drawings, diagrams, schedules, standards, codes and specifications

40

UEENEEE125A

Provide engineering solutions for problems in complex multiple path circuits problems

60

UEENEEE126A

Provide solutions to basic engineering computational problems

60

UEENEEG101A

Solve problems in electromagnetic devices and related circuits

60

UEENEEG102A

Solve problems in low voltage a.c. circuits

80

UEENEEG149A

Provide engineering solutions to problems in complex polyphase power circuits

60

UETTDREL11A

Apply sustainable energy and environmental procedures

20

UETTDREL16A

Working safely near live electrical apparatus

20

UETTDRIS62A

Implement and monitor the power systems organisational OHS policies, procedures and programs

30

UETTDRIS63A

Implement and monitor power systems environmental and sustainable energy management policies and procedures

30

UETTDRSO45A

Operate and monitor system SCADA equipment

150

Total points in core

970

Elective Competency Standard Units

At least a weighting of 1090 points to be achieved. Must achieve at least 140 points from Group D and 440 points from Group E.

Group

Rules

Minimum points

Maximum points

A

Imported and Common Elective Units

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 6. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

0

360

B

Qualification Electives

You may select units from this group to a maximum weighting of 360 points.

0

360

C

Qualification Electives

You may select units from this group to a maximum weighting of 200 points.

0

200

D

Qualification Electives

You must select units from this group with a minimum weighting of 140 points and a maximum weighting of 900 points.

140

650

E

Qualification Electives

You must select units from this group with a minimum weighting of 440 points and a maximum weighting of 1090 points.

440

950

Group A – Imported and Common Elective Units

You may select units from this group to a maximum weighting of 360 points.

Weighting Points

BSBWOR501B

Manage personal work priorities and professional development

60

BSBMGT502B

Manage people performance

70

BSBMGT515A

Manage operational plan

60

BSBINM501A

Manage an information or knowledge management system

50

BSBCUS501C

Manage quality customer service

40

BSBMGT516C

Facilitate continuous improvement

60

BSBINN502A

Build and sustain an innovative work environment

50

BSBLED501A

Develop a workplace learning environment

60

BSBWOR502B

Ensure team effectiveness

60

BSBFIM501A

Manage budgets and financial plans

70

BSBSUS501A

Develop workplace policy and procedures for sustainability

50

TLIF2010A

Apply fatigue management strategies

30

TLIF3063A

Administer the implementation of fatigue management strategies

50

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 6. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

Note: For further information see Application of the NQC Flexibility Formula, Page 10, UET12 Electricity Supply Industry – Transmission, Distribution and Rail Sector Training Package, Version 1, Volume 1 Qualification Framework.

Up to 360 Points

Group B – Qualification Elective Units

You may select units from this group to a maximum weighting of 360 points.

Weighting Points

UEENEEG006A

Solve problems in single and three phase low voltage machines

80

UEENEEH102A

Repair basic electronic apparatus faults by replacement of components

40

UEENEEE102A

Fabricate, dismantle, assemble of utilities industry components

40

UEENEEH112A

Troubleshoot digital sub-systems

80

UEENEEH139A

Troubleshoot basic amplifier circuits

40

UETTDRIS67A

Solve problems in energy supply network equipment

80

UETTDRIS68A

Solve problems in energy supply network protection equipment and systems

40

Group C – Qualification Elective Units

You may select units from this group to a maximum weighting of 200 points.

Weighting Points

UEENEED117A

Install and configure internetworking systems

120

UEENEEI155A

Develop structured programs to control external devices

40

UETTDRDS31A

Draft and layout an power system overhead distribution extension

60

UETTDRDS32A

Draft and layout an power system underground distribution extension

60

UETTDRDS33A

Draft and layout a power system street lighting system

60

UETTDRDS34A

Draft and layout a power system distribution substation minor upgrade

60

Group D – Qualification Elective Units

You must select units from this group with a minimum weighting of 140 points and a maximum weighting of 650 points.

Weighting Points

UEENEEI156A

Develop and test code for microcontroller devices

60

UETTDRDS35A

Design overhead distribution power systems

140

UETTDRDS36A

Design underground distribution power systems

140

UETTDRDS37A

Design power system distribution substations

140

UETTDRDS38A

Design power system public lighting systems

140

UETTDRDS39A

Prepare and manage detailed construction plans for electrical power system infrastructure

140

UETTDRDS42A

Investigate quality of power systems supply issues

140

UETTDRDS43A

Develop high voltage and low voltage distribution protection systems

150

UETTDRDS44A

Design power system zone substations modifications

150

UETTDRDS45A

Organise and implement ESI line and easement surveys

140

UETTDRDS46A

Develop planned power systems outage strategies

140

UETTDRDS49A

Establish and manage power system geographical information systems data

140

UETTDRIS66A

Manage an electricity power system OHS management system

140

UETTDRIS69A

Diagnose and rectify faults in energy supply apparatus

60

UETTDRIS70A

Diagnose and rectify faults in electrical energy distribution systems

60

UETTDRIS71A

Diagnose and rectify faults in electrical energy supply transmission systems

60

UETTDRIS72A

Diagnose and rectify faults in distributed Generation systems

60

UETTDRSO36A

Develop low voltage distribution switching programs

150

UETTDRSO37A

Develop high voltage distribution and subtransmission switching programs

150

UETTDRSO38A

Develop and evaluate power systems transmission switching programs

150

UETTDRSO39A

Coordinate low voltage distribution networks

150

UETTDRSO40A

Coordinate high voltage distribution and subtransmission networks

150

UETTDRSO43A

Coordinate low voltage distribution network demand

150

UETTDRSO46A

Monitor and control the field staff activities

150

UETTDRSO47A

Coordinate high voltage transmission network

150

UETTDRSO48A

Respond to discrete and interdependent protection operations

150

UETTDRSO49A

Coordinate power system operations in a regulated energy market

150

UETTDRTS21A

Maintain interdependent network protection and control systems

150

UETTDRTS22A

Commission interdependent network protection and control systems

150

UETTDRTS25A

Maintain and test and metering schemes

140

UETTDRTS26A

Commission power systems metering schemes

150

UETTDRTS27A

Perform accuracy checks on power systems instrument transformers

150

UETTDRTS28A

Repair, test and calibrate protection relays and meters

150

UETTDRTS29A

Develop power systems secondary isolation instructional documents

150

UETTDRTS31A

Maintain, test and commission power systems voltage regulating equipment

150

UETTDRTS34A

Install and maintain power system communication equipment

150

Group E – Qualification Elective Units

You must select units from this group with a minimum weighting of 440 points and a maximum weighting of 950 points.

Weighting Points

UETTDRDS40A

Prepare and appraise power systems financial impact statements

160

UETTDRDS41A

Manage electrical power systems infrastructure projects

160

UETTDRDS47A

Review power system asset management strategies

150

UETTDRDS48A

Analyse and appraise power system fault and outage data

150

UETTDRDS50A

Design customer power system substations

140

UETTDRDS51A

Manage power system transmission and sub-transmission design process

150

UETTDRDS52A

Design power system transmission, sub-transmission and zone substation buildings

160

UETTDRDS53A

Design power system transmission and sub-transmission substation primary plant

180

UETTDRDS54A

Design power system transmission and sub-transmission protection and control

180

UETTDRDS55A

Design power system transmission and sub-transmission substation earthing

160

UETTDRDS56A

Design power system transmission, sub-transmission and zone substation – civil and structural components

160

UETTDRDS57A

Design power system overhead transmission systems

160

UETTDRDS58A

Design underground transmission systems

160

UETTDRIS73A

Develop engineering solutions for energy supply power transformer problems

60

UETTDRSO32A

Manage power systems network faults

180

UETTDRSO33A

Manage power systems critical events

180

UETTDRSO34A

Control power systems generating plant

180

UETTDRSO35A

Manage high voltage distribution and subtransmission network demand

180

UETTDRSO41A

Manage power systems transmission networks

180

UETTDRSO42A

Manage power systems transmission network demand

180

UETTDRSO44A

Develop crisis power systems management plans

140

UETTDRSO50A

Respond to complex power system protection operations

180

UETTDRSO51A

Manage network systems power flows

180

END OF QUALIFICATION

Custom Content Section

Not applicable.

Our courses are suitable for anyone with the motivation to improve, upskill or reskill. All you need is a computer, laptop, tablet or phone and away you go. You do not need prior qualifications or pre-requisites to complete any of our online courses. If you would like to discuss further, please contact our support team, at any time via live chat on our website, our learning platform.

Be the first to add a review.

Please, login to leave a review
Get course
Enrolled: 0 students
Level: Beginner